제품 소개금속 동봉하는 개폐기

Floor Standing AC420V MV LV Switchgear DC Power Supply Panel

인증
중국 Knkong Electric Co.,Ltd 인증
중국 Knkong Electric Co.,Ltd 인증
제가 지금 온라인 채팅 해요

Floor Standing AC420V MV LV Switchgear DC Power Supply Panel

Floor Standing AC420V MV LV Switchgear DC Power Supply Panel
Floor Standing AC420V MV LV Switchgear DC Power Supply Panel

큰 이미지 :  Floor Standing AC420V MV LV Switchgear DC Power Supply Panel

제품 상세 정보:
원래 장소: 중국
브랜드 이름: KNKONG
인증: ISO IEC GB
모델 번호: DC
결제 및 배송 조건:
최소 주문 수량: 1
가격: USD 1000-2000 Each
포장 세부 사항: 표준 수출 포장
배달 시간: 15 일로 일합니다
지불 조건: L/C (신용장), 전신환
공급 능력: 달 당 1000년 단위

Floor Standing AC420V MV LV Switchgear DC Power Supply Panel

설명
전원 공급기: AC320V~420V 작동 온도: 0C ~ 45C
상대 습도: ≤ 85RH 응용 범위: DC110/220V
제조소: KNKONG OEM / ODM: 이메일에 의한 조사
하이 라이트:

LV DC 전력 공급 패널

,

AC 420V MV LV 개폐기

,

KNKONG MV LV 개폐기

Floor Standing AC420V MV LV Switchgear DC Power Supply Panel
Home Switchgear DC Panel Power Supply

DC Panel Power Supply

Capacity:40 65 80 100 150 200 300AH
Input voltage: AC 380V ±20%;
Stabilization accuracy0.5%
Steady current accuracy0.5%
Ripple coefficient0.5%
Conversion efficiency: 92%
Noise: 55dB
Inquire

Product Introduction

Product overview

To debug the DC screen, turn on the AC power to test whether the AC dual power switching device is working properly and whether the voltage of the lower port of the dual power switching device is normal. After the AC part is tested normally, close the AC switch of the charging module in turn, observe whether the module starts normally, and measure the output voltage and polarity of the module. After the charging module starts normally and the output voltage and polarity are correct, turn on the battery pack switch and each bus switch, measure whether the voltage and polarity of the lower port of the battery pack switch, the closed bus, and the control bus are correct, and observe whether the voltmeter is turned on. anti.

 
Main features
System Features
High reliability:
Adopt modular design of switching power supply, N+1 hot backup.
The charging module can be hot-swapped and unplugged, the average maintenance time is greatly reduced.
The power bus and the control bus can be directly powered by the charging module alone, and can be thermally backed up by the voltage reduction device.
The hardware low-difference independent current sharing technology, the maximum unbalance of the output current between the modules is better than 5%.
Reliable lightning protection and electrical insulation measures, the insulation monitoring device can monitor the insulation of the system in real time to ensure system and personal safety.
The system design adopts IEC, UL and other international standards, and the reliability and safety are fully guaranteed.

 

Technical

Input voltage: AC 380V ±20%;

Stabilization accuracy0.5%

Steady current accuracy0.5%

Ripple coefficient0.5%

Conversion efficiency: 92%

Noise: 55dB

 

연락처 세부 사항
Knkong Electric Co.,Ltd

담당자: Ken Chan (English)

전화 번호: 0086 13938551009

회사에 직접 문의 보내기 (0 / 3000)